Holly Lane, Barwell, Leicestershire, LE9 8BT
Enquiries@HiskinsElectrical.co.uk
| Quote Number | QUO-3388 |
| Quote Date | 8th February 2024 |
| Valid Until | 9th March 2024 |
| Total | £240.00 |
108 Hinckley Road, Earl Shilton LE9 7LD
1. Install correct secondary circuit protection device to central heating circuit.
2. Investigation of circuit 7 which has a higher than acceptable r2 reading and earth loop impedance (R1+R2) reading.
3. Investigation of circuit 10 which has a higher than acceptable earth loop impedance (R1+R2) reading.
5. Investigation of continuity of circuit protective conductor at lighting accessory in bathroom.
| Hrs/Qty | Service | Rate/Price | Sub Total |
|---|---|---|---|
| 1 | Materials and Labour. Cost to supply materials and labour to install them to complete works as described above. |
£240.00 | £240.00 |
| 1 | Testing and certification as required to comply with Part P of the building regulation including notification to your local authority. Included as part of our service. |
£0.00 | £0.00 |
| Sub Total | £240.00 |
| VAT Not Applicable | £0.00 |
| Total | £240.00 |